Abendl Module Code, Name OF2 DMSITS OF3 DMSITS OF4 l)MSTTS OF6 DMSITS OF7 DMSFRE OF8 DMSFRE 101 DMSSVN 104 DMSVIB 155 DMSSLN Cause of Abend
The CMS nesting level of 20 has been exceeded. CMS SVC (202 or 203) in-
struction was executed and
provl.sl.on was made for an
error return from the rou-
tine processing the SVC. The DMSKEY key stack over-
flowed. ThA nMSKRV kAy flowed.
The DMSKEY key stack was
not empty when control re-· turned from a command or
function. Occurs when TYPCALL=SVC (the default) is specified
in the DMSFREE or DMSFRET macro. Occurs when TYfCALL=BALR is
specified in the DMSFREE or DMSFRET Macro devices.
The wait count specified in
an OS WAIT macro was larger
than the number of ECBs
specified.
The OS interface to VSAM is unable to
execution of the
program. DOS/VS continue
problem
Error during LOADMOD after
an OS LINK, LOAD, ICTL, or
ATTACH. The compiler switch
is on.
Figure 24. CMS Abend Codes (Part 2 of 4)
Action
None. abend recovery
takes place when the
next command is en­
tered. Inter DEBUG and type GO. Control returns to
the point to which a
normal return would
have been made. Inter DEBUG and type GO. Execution conti­
nues and the DftSKEY macro is ignored.
Enter DEBUG and type GO. Control returns
from the command or
function as if the key
stack had been empty. When a system abend
occurs, use DEBUG to
attempt recovery. When a system abend
occurs, use DEBUG to
attempt recovery.
Examine the program for excessive wait
count specification. See the additional er­
ror message accompany­
ing the abend message,
correct the error, and
reexecute the program. See the last LOADftOD (DMSMOD) error message
for error description.
In the case of an I/O error, recreate the
module. If the module
is missing, create it.
2-244 IBM VM/370 System Logic and Program Determination--Volume 2
L- Abendl Module Code I Name
15A
174
177 240 400 704 705 804 80A 905 90A DMSSLN DMSVIB DMSVIB DMSVIP DMSSVT DMSSVT DMSSMN DMSSMN DMSSMN DMSSMN Cause of Abend Severe error during load
(phase not found) after an OS LINK, LOAD, ICTL, or
ATTACH. The compiler switch
is on.
The as interace to DOS/VS VSAM is unable to continue
execution of the problem
program.
The as interface VSAM is unable to
execution of the
program.
to DOS/VS continue
problem
No work area vas provided
in the parameter list for
an as RDJFCB macro.
An invalid or unsupported
form of the as XDAP macro
was issued by the problem
program.
An as GETMAIN macro (SVC 4)
vas issued specifying the
LC or 1U operand. These
operands are not supported
by CMS. An as FREEMAIN macro (SVC 5) issued ing the L operand. This
operand is not supported by CMS. An as GETMAIN macro (804- SVC 4, 80A - SVC 10) was
issued that requested ei­
ther zero bytes of storage,
or more storage than was
available.
An as FREEMAIN macro (905 - SVC 5, 90A - SVC 10) was
issued specifying an area
to be released whose ad­
dress was not on a double­
word boundary.
Figure 24. CMS Abend Codes (Part 3 of 4)
Action See last LOAD error message (DMSLIO) for
the error description.
In the case of an I/O error, re-create the
text deck or TXTLIB. If either is missing,
create it. See the additional er­
ror message accompany­
ing the abend message,
correct the error, and
reexecute the program. See the additional er­
ror message accompany­
ing the abend message, correct the error, and
reexecute the program. Check RDJFCB specifi­
cation.
Examine program for
unsupported XDAP macro
or for SVC O. Change the program so
that it specifies
allocation of only one
area at a time. Change the program
that it specifies release of only
area at a time.
so
one Check the program for
a valid GETMAIN re­
quest. If more storage
was requested than vas
available, increase
the size of the virtu­
al machine and retry. Check the program for
a valid FREEMAIN re­
guest; the address may have been incorrectly
specified or modified. CMS Diagnostic Aids 2-245
Previous Page Next Page