logon tester
ENTER PASSWORD: FILES: 001 RDR, NO PRT, NO PUN (see Note 1) LOGON AT 08:19:52 EST MONDAY 01/12/76
set ecmode on
link dosys 250 250 w
(see Note 2) DASD 250 LINKED R/W ipl 250 (see Note 3) OI03A SPECIFY SUPERVISOR NAME $$a$sup2 01041 IPLDEV=X'250',VOLSER=DOSRE3,CPUID=FF0101530155 01301 DATE=01/12/76,CLOCK=16/35/09,ZONE=EAST/04/00 OI10A GIVE IPL CONTROL COMMANDS set (see Note 4)
dpd 01521 PAGE DATA SET EXTENT LOW HIGH
327 0 250 11 01201 DOS/VS IPL COMPLETE BG lIOOA READY FOR COMMUNICATIONS. BG (see Note 5)
log
BG
assgn sysrec,x'250'
BG
set rf=yes
BG
(see Note 6)
BG
// JOB TESTl DATE 10/30/75,CLOCK 16/35/47
BG
1I89A IPL REASON CODE = (see Note 7)
BG lI91A SUB-SYSTEM ID =
BG 11931 RECORDER FILE IS 2% FULL BG 1/ OPTION NODECK (see Note 8)
BG
// EXEC ASSEMBLY BG EOJ TEST1 DATE 10/30/75,CLOCK BG lCOOA ATTN. OOC BG
(see Note 10) BG OP08A INTERV REQ 16/37/49,DURATION (see Note 9) SYSRDR=OOC 00/02/01 ._--_., I I I I Figure 16. IPL DOS/VS and Execute a Job in the Card Reader (Part 1 of 2)
88 IBM VM/370 Operating Systems in a Virtual Machine
The reader file contains a job stream for the DOS/VS virtual
machine a 2. The DOS/VS system residence is assumed to be defined at virtual
address 250 in userid DOSYS's directory entry and have a write
password of ALL.
3. After the 1PL command, the attention interruption causes message OI03A to be issued. After entering the supervisor name, a later continues the 1PL procedure.
4. The SET and DPD commands are required to IPt DOS/VS. 5. The background partition is active and waiting for commands. The LOG command is optional; the ASSGN and SET commands shown here
may be required for system recordinq. 6. A null line signals an interruption to the card reader, so that DOS/VS begins reading the job stream.
7. These are ROE (reliability data extractor) messages; a null line
entered in response indicates that the user is taking the default
values.
8. DOS/VS continues reading the job.
9. The card reader is empty; the spool file has been read. 10. A null line causes another interrupt to the card reader; if
another file is in the card reader g it is read. Otherwise,
message OP08A is issued.
Figure 16. IPL DOS/VS and Execute a Job in the Card Reader (Part 2 of 2) 1PL FROM THE CARD READER Place the centrol commands for performing the IPL procedure in the card
reader of the DOS/VS virtual machine before issuing the IPL command to
lead the system. Then, signal DOS/VS to read the control commands from
the card reader. This method can be more efficient than entering all of
the control commands manually, especially if there are many ADD and DEL commands that must be issued when initializing DOS/VS. The cards required to perform the 1PL procedure must be in two
separate card files: (1; a single card specifying the supervisor name, and (2) a card deck containing the IPL commands. A user may follow
these card files with additional files that contain jobs for execution
in the DOS/VS virtual machine.
To load DOS/VS into the virtual machine, enter the 1Ft command:
ipl 250 Section 3. DOS/VS in a Virtual Machine 89
Previous Page Next Page