EO 176
EA 1S6 V"F1IL DC V"F1ILLP EQU V"FAILOT EQU V"F1IL1 DS V"KEYS EQU C'VMF1ILURE=' Failure keyword *+4 End of VMF1IL if loop or
perfor.ance failure
*+5 End of VMFAIL if other failure CL11 Failure type * Length of base keys **** OTHER KEYWORDS WHICH M1Y OR ftAY NOT EE USlD FOLLOW**** C5 197 C9 201 D2 210 DS 216 DC 220 E3 227
E7 231
EB 235
F3 243 FB 251 14C 332 150 336
152 33S 1A2 41S MODLN DC VftMOD DC VftMOD 1 DS
DISPLN DC VMDISP DC VMDISP1 DS ENTRYLN DC V!!ENTRY DC VftENTRY1 DS DC SUPPORT DS SUPPLN DC SUPP1 DC SUPP2 DC X'00130000' C'V!!MODULE=' CL6 X ' 00 OF 0000 ' C'VMDISP=' CL4 X'00140000' C'YMENTRY=' CLS SOC' , F X'0050' SOC' , 320C' , Length of .odule na.e ftodule na.e keyword
Failing module nalle Displace.ent key area length
Displacement keyword Disp1acellent Entry point key area length
Entry point keyword Entry point address Padded for additional key Supporting data area
Supp1e.entary data area length
initially set
Supporting data reserved fer
the dump fileid User supporting data area **** THE PROBLE!! REPORT TEXT IREI FOLLOWS: ****
2E2 73S TEXT DC X'01EO' Text area length initially set to 4S **** THE FIRST 4S0 BYTES RESERVED FOR THE !XTRACTION PROGR1! **** 2E4 740 334 S20 384 900 3D4 9S0 424 1060 474 1140 TEXTI TEXT1 TEXT2 TEXT3 TEXT4 TEXT5 DC DC DC DC DC DC SOC' , SOC' , SOC' SOC' , SOC' SOC' Data extraction text line a
Data extraction text line 1
Data extraction text line 2
Data extraction text line 3
Data extraction text line 4 Data extraction text line 5
**** USER TEXT IREI UP 15 LINES OF SO EYTE ENTRIES ****
Figure 2-3. V!!FDUMP Shared Constant lrea (Part 4 of 4) 56 IBM YM/370 Service Routines Program Logic
INTSECT -- VMFDUMP AND PROB INTERNAL DATA AREA 00 04 08 OC 10 INTSEV 14
18
1C 20 24
<
3C 1 I 30 I <
< 1 S8 1 <
< 1-------- 7C I <
< Hex Dec --CO -CO 00 00 03 03 09 09 OA 10 OB 11 10 16
11 17
12 18
13 19
13 19
1B 27
1C 28
21 33
26 38
3F 63
42 66
sa aa
7C 124 INTSECT INTCPUT IHTSER IHTSDA INTSUBC INTTIME INTSEV INTBYPS INTPDC INTERRT
INTED
INTFILL IHTET INTPNUM INTTOOL INTPLC INTDUMM INTI1 INTX2 INTCPUT INTSER INTSDA INTBYPS DSECT DS CL3 DS CL6 DS CL1 DS CL1 DS CLS DS CL1 DS CL1 DS CL1 DS OCL14 DS CLa DS CL1 DS CLS DS CLS DS CL2S DS CL3 DS CL22 DS CL36 DS CL36
INTET INTEX1 INTX2 CPU type CPU serial INTSUEC INTPIC INTPNUM INTTIME INTED ..- I INTFILL INTTOOL INTPLC INTDUMM support data available switch
Sub.itter's code
Total time expended
Proble. severity
Bypass required switch
Filler
Error date and ti.e
Date of error
Filler
Ti.e of error
Syste.-assigned problem nu.ber
Tool usage codes PLC level of syste.
Filler VMFIILURE (internal use only) VMENVIR (internal use only)
Figure 2-4. VMFDUMP and PROB Internal Data Area
> I ; >
> 1 I >
> I I >
>
Chapter 2. IPCS--Tbe Interactive Proble. Centrol Syste. 57
Previous Page Next Page