8.80 IPL (IPL Normal from device xxxx)

8.80.1 Function

This console command performs the Initial Program Load (IPL) Normal manual function from the given
device. The IPL command may also be used to perform a load from CD-ROM or server. For example if a
standard SUSE S/390 Linux distribution CD is loaded and mounted on /cdrom, this CD-ROM may then be
IPL’ed using ”IPL /cdrom/suse.ins”.

If the first operand is a device name (devnum is a 1- to 4-digit hexadecimal number), a CCW-type IPL is
initiated from the indicated device number and SCLP disk I/O is disabled.

If the first operand is a filename a list-directed IPL is performed from the specified ".ins" file and SCLP
disk I/O is enabled for the directory path where the ".ins" file is located.

An optional ‘LOADPARM’ keyword followed by a 1-8 character string can be used to set the LOADPARM
prior to IPL.

An optional 'PARM' keyword followed by a string can also be passed to the IPL command processor. The
string will be loaded into the low-order 32 bits of the general purpose registers (4 characters per register
for up to 64 bytes). The PARM option behaves similarly to the VM IPL command.

An optional 'CLEAR' keyword will initiate a Load Clear manual control function, prior to starting an IPL.

8.80.2 Syntax

Descriptive

filenameiplparm parmstring]

Diagram

¬¬¬¬§¬¬¬§¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬§¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬Ê



filename
iplparm ¬¬¬«






parmstring

ʬ¬¬§¬¬¬¬¬¬¬¬¬¬¬¬¬§¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬ÊÍ


8.80.3 Parameter

devnum

The device address from which the emulator will IPL the system.

filename

The name of a ".ins" file to be loaded.

LOADPARM

This is the optional LOADPARM keyword.

iplparm

This is an 1-8 byte character string used to set the LOADPARM prior to the IPL.

The parameter is operating system dependent, consult the relevant operating
system documentation for details.

PARM

This is the optional PARM keyword.

parmstring

The character string (max. 64 bytes) to be passed to the IPL command processor.
The character string will be loaded into the low-order 32 bits of the GPRs (4
characters per register).

CLEAR

Initiate a Load Clear manual control function, prior to starting an IPL.

8.80.4 Examples

Example 1:

IPL normal from device 0148.

HHC00013I Herc command: 'ipl 0148'

HHC01315I 0:00C2 CH: ccw 03000000 20000001=>040C0000 0001CEFA 00000000 00000000 ................

HHC01312I 0:00C2 CH: stat 0200, count 0001 ''

HHC01313I 0:00C2 CH: sense 40000000 00000000 00000000 00000000 00000000 00000000

HHC01314I 0:00C2 CH: sense INTREQ

HHC01315I 0:00C3 CH: ccw 03000000 20000001=>040C0000 0001CEFA 00000000 00000000 ................

HHC01312I 0:00C3 CH: stat 0200, count 0001 ''

HHC01313I 0:00C3 CH: sense 40000000 00000000 00000000 00000000 00000000 00000000

HHC01314I 0:00C3 CH: sense INTREQ

HHC01315I 0:00C4 CH: ccw 03000000 20000001=>040C0000 0001CEFA 00000000 00000000 ................

HHC01312I 0:00C4 CH: stat 0200, count 0001 ''

HHC01313I 0:00C4 CH: sense 40000000 00000000 00000000 00000000 00000000 00000000

HHC01314I 0:00C4 CH: sense INTREQ

HHC01315I 0:00C5 CH: ccw 03000000 20000001=>040C0000 0001CEFA 00000000 00000000 ................

HHC01312I 0:00C5 CH: stat 0200, count 0001 ''

HHC01313I 0:00C5 CH: sense 40000000 00000000 00000000 00000000 00000000 00000000

HHC01314I 0:00C5 CH: sense INTREQ

HHC01315I 0:0480 CH: ccw 03000000 20000001=>040C0000 0001CEFA 00000000 00000000 ................

HHC01312I 0:0480 CH: stat 0200, count 0001 ''

HHC01313I 0:0480 CH: sense 40220000 00C00300 00000000 00800100 010000FF FF000000

HHC01314I 0:0480 CH: sense INTREQ EOC WRI

HHC01315I 0:0481 CH: ccw 03000000 20000001=>040C0000 0001CEFA 00000000 00000000 ................

HHC01312I 0:0481 CH: stat 0200, count 0001 ''

HHC01313I 0:0481 CH: sense 40220000 00C00300 00000000 00800100 010000FF FF000000

HHC01314I 0:0481 CH: sense INTREQ EOC WRI

.

.

.

Figure 163: IPL command

Previous Page Next Page