8.167 STOP (Stop CPU or printer / punch device)

8.167.1 Function

The STOP command by itself (without argument) simply stops a started CPU, whereas STOP devicenum
presses the (virtual) stop button on printer or punch device devicenum

8.167.2 Syntax

Descriptive

]

Diagram

¬§¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬ÊÍ



8.167.3 Parameter

devicenum

The device number of the printer or punch device which should be stopped-

8.167.4 Examples

Example 1:

Stop the printer device 000E.

HHC00013I Herc command: 'stop 000e'

HHC02214I 0:000E device stopped

Figure 302: STOP command (stop printer)

Example 2:

Stop CPU 1.

HHC00013I Herc command: 'cpu 1'

HHC00013I Herc command: 'stop'

HHC00834I Processor CP01: manual state selected

Figure 303: STOP command (stop CPU)

8.168 STOPALL (Stop all CPUs)

8.168.1 Function

The STOPALL command stops all CPUs

8.168.2 Syntax

Descriptive

Diagram

PALL ¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬ÊÍ

8.168.3 Parameter

None.

8.168.4 Examples

Example 1:

Stop all CPU’s.

HHC00013I Herc command: 'stopall'

Figure 304: STOPALL command

Previous Page Next Page