8.177.4 Examples

Example 1:

Turn instruction tracing on.

HHC00013I Herc command: 't+'

HHC02229I Instruction tracing on

HHC02267I CP00: PSW=0000014800000080 INST=05F0 BALR 15,0 branch_and_link_register

HHC02267I CP00: GR00=00000000 GR01=00000000 GR02=00000000 GR03=00000000

HHC02267I CP00: GR04=00000000 GR05=00000000 GR06=00000000 GR07=00000000

HHC02267I CP00: GR08=00000000 GR09=00000000 GR10=00000000 GR11=00000000

HHC02267I CP00: GR12=00000000 GR13=00000000 GR14=00000000 GR15=00000000

HHC02267I CP00: PSW=0000014800000082 INST=980E0010 LM 0,14,16(0) load_multiple

HHC02267I CP00: R:00000010:K:06=00000000 00000000 00000000 00000000 ................

HHC02267I CP00: GR00=00000000 GR01=00000000 GR02=00000000 GR03=00000000

HHC02267I CP00: GR04=00000000 GR05=00000000 GR06=00000000 GR07=00000000

HHC02267I CP00: GR08=00000000 GR09=00000000 GR10=00000000 GR11=00000000

HHC02267I CP00: GR12=00000000 GR13=00000000 GR14=00000000 GR15=40000082

HHC02267I CP00: PSW=0000014880000086 INST=41A0F05A LA 10,90(0,15) load_address

HHC02267I CP00: R:000000DC:K:06=41800100 41A0F08A 1B984700 F06E5890 ......0..q..0>..

HHC02267I CP00: GR00=00000000 GR01=00000000 GR02=00000000 GR03=00000000

HHC02267I CP00: GR04=00000000 GR05=00000000 GR06=00000000 GR07=00000000

HHC02267I CP00: GR08=00000000 GR09=00000000 GR10=00000000 GR11=00000000

HHC02267I CP00: GR12=00000000 GR13=00000000 GR14=00000000 GR15=40000082

HHC02267I CP00: PSW=000001488000008A INST=D200FC7D0008 MVC 3197(1,15),8(0) move_character

HHC02267I CP00: R:00000CFF:K:06=F1 E5D5C9D7 D458FFFF 76B3BD00 AAAAFF 1VNIPM.....]....

HHC02267I CP00: R:00000008:K:06=F1000000 00000000 00000000 00000000 1...............

HHC02267I CP00: GR00=00000000 GR01=00000000 GR02=00000000 GR03=00000000

HHC02267I CP00: GR04=00000000 GR05=00000000 GR06=00000000 GR07=00000000

HHC02267I CP00: GR08=00000000 GR09=00000000 GR10=000000DC GR11=00000000

HHC02267I CP00: GR12=00000000 GR13=00000000 GR14=00000000 GR15=40000082

HHC02267I CP00: PSW=00000148C0000090 INST=95000009 CLI 9(0),0 compare_logical_immediate

HHC02267I CP00: R:00000009:K:06=000000 00000000 00000000 00000000 00 ................

HHC02267I CP00: GR00=00000000 GR01=00000000 GR02=00000000 GR03=00000000

HHC02267I CP00: GR04=00000000 GR05=00000000 GR06=00000000 GR07=00000000

HHC02267I CP00: GR08=00000000 GR09=00000000 GR10=000000DC GR11=00000000

HHC02267I CP00: GR12=00000000 GR13=00000000 GR14=00000000 GR15=40000082

HHC02267I CP00: PSW=0000014880000094 INST=4780F050 BC 8,80(0,15) branch_on_condition

HHC02267I CP00: R:000000D2:K:06=6800 FD2E2820 28402860 41800100 41A0 ....... .-......

HHC02267I CP00: GR00=00000000 GR01=00000000 GR02=00000000 GR03=00000000

HHC02267I CP00: GR04=00000000 GR05=00000000 GR06=00000000 GR07=00000000

HHC02267I CP00: GR08=00000000 GR09=00000000 GR10=000000DC GR11=00000000

HHC02267I CP00: GR12=00000000 GR13=00000000 GR14=00000000 GR15=40000082

.

.

.

Figure 315: T+ command

8.178 T- (Instruction trace off)

8.178.1 Function

This command turns off the instruction tracing function.

8.178.2 Syntax

Descriptive

T-

Diagram

Êʬ¬¬ T- ¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬ÊÍ

8.178.3 Parameter

None.

8.178.4 Examples

Example 1:

Turn off instruction tracing.

HHC00013I Herc command: 't-'

HHC02229I Instruction tracing off range 1000000-1001000

Figure 316: T- command