8.182 TIMERINT (Display or set timers update interval)
8.182.1 Function
The TIMERINT parameter displays or sets the internal timer update interval in microseconds. This para-
meter specifies how frequently Hercules's internal timers-update thread updates the TOD clock, CPU
Timer and other architectural related clock and timer values.
The default interval is 50 microseconds which attempts to strike a reasonable balance between clock
accuracy and overall host performance.
8.182.2 Syntax
Descriptive
]
Diagram
¬¬¬¬ ¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬ÊÍ
8.182.3 Parameter
interval
Specifies the timer update interval in microseconds. The minimum allowed value for
the interval is 1 microsecond and the maximum is 1'000'000 microseconds (one se-
cond.
CAUTION: While a lower TIMERINT value may help increase the accuracy of the
guest's TOD clock and CPU Timer values, it could also have severe negative im-
pact on the overall performance of the host operating system. This is especially
true when a low value is coupled with a high HERCPRIO and TODPRIO priority
setting.
Exercise extreme caution when choosing your desired TIMERINT in relationship to
your chosen HERCPRIO and TODPRIO priority settings.