5.63 QUITMOUT (Quit timeout value)

5.63.1 Function

QUITMOUT is used for setting the timeout value for a second QUIT, EXIT or SSD command if Hercules is
built with the option “OPTION_SHUTDOWN_CONFIRMATION”. If Hercules is built without this option,
then the QUITMOUT system parameter cannot be specified in the configuration file.

5.63.2 Syntax

Descriptive

nn

Diagram

Êʬ¬¬ ¬¬¬ nn ¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬ÊÍ





5.63.3 Parameter

nn

This specifies the timeout value where nn must be in the range of 2 to 60 seconds.
If the timeout value is 0 then no second QUIT, EXIT or SSD command is neces-
sary.

5.63.4 Examples

Example 1:

Set the quit timeout value to 30 seconds.

QUITMOUT 30

5.64 REXX (REXX interpreter settings)

5.64.1 Function

The REXX system parameter is used to manage the Rexx interpreter settings. It allows to specify the
paths where the Rexx executables can be found and what extensions for the executables are to be used.
If Hercules is built with support for both Rexx environments (Regina Rexx and Open Object Rexx) then
the desired environments can be enabled or disabled. The message prefixes to be used for Rexx mes-
sages (issued through the “say” command) and error messages (issued through the Rexx interpreter) can
be set separately.

5.64.2 Syntax

Descriptive

option


where option

path [delimiter path ...

suffix [delimiter suffix ...]

messageprefix

errorprefix

Diagram

option ¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬ÊÍ


where option


¬¬¬§¬¬¬§¬¬¬¬¬¬¬¬¬¬¬¬¬¬§¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬«


¬¬¬ ¬¬¬«




Previous Page Next Page