5.13 CMDSEP (Command line separator) ........................................................................................ 60 5.14 CNSLPORT (Console port) ....................................................................................................... 61 5.15 CODEPAGE (Codepage conversion table) ............................................................................... 62 5.16 CONKPALV (Console and telnet clients keep-alive option) ...................................................... 64 5.17 CP_UPDT (User character conversion table) ........................................................................... 66 5.18 CPUIDFMT (Set format BASIC / 0 / 1 STIDP generation) ........................................................ 69 5.19 CPUMODEL (CPU model number) ........................................................................................... 71 5.20 CPUPRIO (CPU thread process priority) .................................................................................. 72 5.21 CPUSERIAL (CPU serial number) ............................................................................................ 73 5.22 CPUVERID (CPU version code) ............................................................................................... 74 5.23 DEFSTORE (Define main and expanded storage) ................................................................... 75 5.24 DEFSYM (Define a symbol) ...................................................................................................... 79 5.25 DEVPRIO (Device threads process priority) ............................................................................. 80 5.26 DEVTMAX (Maximum number of device threads) .................................................................... 81 5.27 DIAG8CMD (DIAGNOSE 8 command option) .......................................................................... 83 5.28 ECPSVM (ECPS:VM support status (VM)) ............................................................................... 85 5.29 ENGINES (Processor engines type) ......................................................................................... 87 5.30 HAO (Hercules Automatic Operator) ......................................................................................... 89 5.31 HERCLOGO (Hercules logo file) ............................................................................................... 91 5.32 HERCPRIO (Hercules process priority) .................................................................................... 92 5.33 HTTP (HTTP server configuration)............................................................................................ 93 5.34 HTTPPORT (HTTP server port) ................................................................................................ 95 5.35 HTTPROOT (HTTP server root directory) ................................................................................. 96 5.36 IGNORE (Ignore subsequent INCLUDE errors) ........................................................................ 97 5.37 INCLUDE (Include configuration file) ........................................................................................ 98 5.38 IODELAY (I/O interrupt wait time (LINUX)) ............................................................................... 99 5.39 LDMOD (Additional dynamic load modules) ........................................................................... 101 5.40 LEGACYSENSEID (SENSE ID CCW (x'E4') feature) ............................................................. 102 5.41 LOADPARM (IPL parameter) .................................................................................................. 104 5.42 LOGOPT (Logging options) ..................................................................................................... 105 5.43 LPARNAME (LPAR name returned by DIAG x'204') .............................................................. 106 5.44 LPARNUM (LPAR identification number) ................................................................................ 107 5.45 MAINSIZE (Main storage size) ................................................................................................ 109 5.46 MANUFACTURER (STSI manufacturer code) ........................................................................ 112 5.47 MAXCPU (Maximum number of CPUs) .................................................................................. 113 5.48 MAXRATES (MIPS/SIO rate reporting interval) ...................................................................... 115 5.49 MEMLOCK (Lock Hercules memory) ...................................................................................... 117 5.50 MODEL (STSI model code) ..................................................................................................... 118 5.51 MODPATH (Dynamic load module path) ................................................................................ 120 5.52 MOUNTED_TAPE_REINIT (Control tape initialization) .......................................................... 121 5.53 MSGHLD (Timeout value of held messages) .......................................................................... 123 5.54 MSGLEVEL (Message display output) .................................................................................... 124 5.55 MSGLVL (Message display output) ........................................................................................ 127 5.56 NUMCPU (Number of emulated CPUs) .................................................................................. 128 5.57 NUMVEC (Number of vector facilities) .................................................................................... 130 5.58 OSTAILOR (Tailor trace information for specific operating system) ....................................... 131
5.59 PANRATE (Console refresh rate) ........................................................................................... 133 5.60 PANTITLE (Console window title) ........................................................................................... 135 5.61 PGMPRDOS (LPP license setting) ......................................................................................... 137 5.62 PLANT (STSI plant code) ........................................................................................................ 138 5.63 QUITMOUT (Quit timeout value) ............................................................................................. 139 5.64 REXX (REXX interpreter settings)........................................................................................... 140 5.65 SCLPROOT (SCLP base directory) ........................................................................................ 145 5.66 SCPECHO (Echo to console and history of SCP replies) ....................................................... 146 5.67 SCPIMPLY (Pass non-Hercules commands to the SCP) ....................................................... 147 5.68 SCSIMOUNT (Automatic SCSI tape mounts) ......................................................................... 148 5.69 SHCMDOPT (Shell command option) ..................................................................................... 149 5.70 SHOWDVOL1 (Enable showing of DASD volsers in device list) ............................................ 151 5.71 SHRDPORT (Shared device server port) ............................................................................... 152 5.72 SRVPRIO (Server threads priority) ......................................................................................... 154 5.73 SYMPTOM (Instruction trace display option) .......................................................................... 155 5.74 SYSEPOCH (Base date for TOD clock) .................................................................................. 156 5.75 TIMERINT (Internal timer update interval) .............................................................................. 158 5.76 TODDRAG (TOD clock drag factor) ........................................................................................ 160 5.77 TODPRIO (Timer thread process priority) ............................................................................... 161 5.78 TRACEOPT (Instruction trace display option) ......................................................................... 162 5.79 TZOFFSET (TOD clock offset from GMT) .............................................................................. 163 5.80 XPNDSIZE (Expanded storage size) ...................................................................................... 164 5.81 YROFFSET (TOD clock offset from actual date) .................................................................... 167 5.82 Process and Thread Priorities ................................................................................................. 168 6. Device Definition Descriptions ........................................................................................................... 170 6.1 Local non-SNA 3270 Devices ..................................................................................................... 170 6.2 Integrated 3270 (SYSG) Console ............................................................................................... 173 6.3 Console Printer-Keyboard Devices ............................................................................................. 176 6.4 Integrated Console Printer-Keyboard Devices ........................................................................... 179 6.5 Card Reader Devices .................................................................................................................. 180 6.6 Card Punch Devices ................................................................................................................... 183 6.7 Line Printer Devices .................................................................................................................... 185 6.8 Emulated Tape Devices .............................................................................................................. 189 6.9 Channel-to-Channel Adapters .................................................................................................... 208 6.10 FBA DASD Devices ................................................................................................................. 222 6.11 CKD D
ASD De
vices ................................................................................................................
224 6.12 Communication Lines .............................................................................................................. 228 7. Hercules Console ............................................................................................................................... 232 7.1 Hercules Hardware Console ....................................................................................................... 232 7.2 Web browser interface ................................................................................................................ 234 7.3 Using the keyboard ..................................................................................................................... 235 7.4 Log formats ................................................................................................................................. 238 7.5 Programmed Function Key (PF Key) Support ............................................................................ 240 7.6 Hercules Console Commands (sorted alphabetically) ................................................................ 243 7.7 Hercules Console Commands (grouped by functionality)........................................................... 250 8. Console Command Descriptions ........................................................................................................ 259
Previous Page Next Page