8.92 LPARNUM (Display or set LPAR i
dentification number)
8.92.1 Function
The LPARNUM console command displays or set the LPAR identification number. It specifies the one- or
two-digit hexadecimal LPAR identification number stored by the STIDP instruction, or BASIC. If a one-
digit number from 1 to F (hexadecimal) is specified, then STIDP stores a format-0 CPU I
D, unless a sub-
sequent “CPUIDFMT 1” statement is specified. If zero or a two-digit hexadecimal number, except 10 (he-
xadecimal), is specified, then STIDP stores a format-1 CPU I
D. For LPARNUM 10 the current CPUIDFMT
is not changed. If LPARNUM is BASIC, then the STIDP instruction stores a basic-mode CPU ID. The de-
fault is LPARNUM 1 with a format-0 CPU I
D.
8.92.2 Syntax
Descriptive
n nn]
Diagram
¬¬¬¬¬§¬¬¬¬¬¬¬¬¬¬¬ ¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬ÊÍ
¬¬ ¬¬¬«
1...F
¬¬¬«
¬¬
¬¬¬¬¬«
¬¬ ¬ nn ¬¬¬¬
8.92.3 Parameter
BASIC
Specifies that STIDP stores a basic-mode CPU ID.
1 … F
Specifies the one-digit hexadecimal LPAR identification number. The STIDP in-
struction stores a format-0 CPU ID, unless a subsequent “CPUIDFMT 1” statement
is specified.
0
Specifies 0 as LPAR identification number. The STIDP instruction stores a format-1
CPU I
D.
nn
Specifies the two-digit hexadecimal LPAR identification number (except 10 hexa-
decimal). For LPARNUM 10 the current CPUIDFMT is not changed. The STIDP in-
struction stores a format-1 CPU I
D.