Example 2:

Disable global CTCI-WIN debug tracing.

HHC00013I Herc command: 'tt32 nodebug'

HHC02204I TT32 debug set to disabled

Figure 333: TT32 NODEBUG command

Example 3:

Display TunTap32 statistics for device 0E20.

HHC00013I Herc command: 'tt32 stats 0e20'

HHC04101I D:\Hercules\TunTap32.dll Statistics:

Size of Kernel Hold Buffer: 1024K

Size of DLL I/O Buffer: 64K

Maximum DLL I/O Bytes Received: 4K

0 Total Write Calls

0 Total Write I/Os

0 Packets To All Zeroes MAC Written

0 Total Packets Written

0 Total Bytes Written

346 Total Read Calls

1770 Total Read I/Os

0 Internally Handled ARP Packets

0 Packets From Ourself

913 Total Ignored Packets

0 Packets To All Zeroes MAC Read

950 Total Packets Read

524372 Total Bytes Read

Figure 334: TT32 STATS command

8.188 TZOFFSET (Set TOD c
lock offset from GMT)

8.188.1 Function

The TZOFFSET command is used to define the offset of the TOD clock from the current system time. For
GMT use the default value (0000). This is also the correct setting if your system time (the time of the ope-
rating system on which Hercules is running) is set to local time rather than GMT. For time zones west of
Greenwich specify a negative value (example: -0500 for US Eastern Standard Time, -0800 for US Pacific
Standard Time). For time zones east of Greenwich, specify a positive value (example: +0100 for Central
European Time, +0930 for South Australian Time).

8.188.2 Syntax

Descriptive

+ hhmm -hhmm

Diagram

+hhmm ¬¬¬§¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬ÊÍ




-hhmm

8.188.3 Parameter

+hhmm

Use a positive time in hours and minutes for time zones east of Greenwich.

-hhmm

Use a negative time in hours and minutes for time zones west of Greenwich.

8.188.4 Examples

Example 1:

Set the offset of the TOD clock from the current system time to Central European Time.

HHC00013I Herc command: 'tzoffset +0100'

HHC02204I tzoffset set to +0100

Figure 335: TZOFFSET command