Upd. a ting IPCS Updating I pes Modules You can use the same procedures used to update VM/310 CP, CKS, or RSCS modules to update IPCS modules. Since there is no nucleus associated
with the IPCS component, the procedure is simplified.
If you have the IPCS source files on MAINT's 394, and the PTFs and
update files on 294, then, to reassemble an IPCS module, you might have
the search order as
1 q 1
294 394 390 A BIA ,.. ,.,. .... , ... S R/W RIO 1) ", ,..., RIO you could then use the VMFASM EXEC to assemble the module, for example:
vmfasm dmmpro DMMRnO To generate the new IPCS commands, you should use the LOAD and GENMOD commands to generate the new command modules from updated text files on MAINT's 191, and nonupdated text files from the 194. Once the new IPCS module has been generated, copy it to the CMS S-disk (MAINT's 190). For
example, you issue the commands:
access 195 a
access 191 b/a
access 194 cia The command names, and the CMS commands you need to issue to generate
them, are shown in Figure 39. r -------------------------------------------------------------, I IPCS Command Name I FROB DUMPSCAN VMFDUMP STAT SUMMARY L CMS Commands to Generate
load dmmpro genmod prob
load dmmdsc
genmod dumpscan
load dmmedm
genmod vmfdump (to dmmext
genmod vmfdump2 (from dmmext
load dmmsta
genmod stat
load dmmsum
genmod summary
Figure 39. IPCS Command Names Part 5. Updating VM/310 361
368 Planning and System Generation Guide
Previous Page Next Page