CPTYPE= {EP } CPNAME=ncpname BASEADD=ccu 3704/3705 Control Program
indicates which set address (SAD) command must be
issued prior to enabling the emulator lines.
indicates which type of 3704/3705 control program is
run in this 3704/3705. The valid adapter types are as follows: I , I CPTYPE= , I , ADAPTER= , EP I ,TYPE 1 Yes 1 TYPE2 No I TYPE3 No , TYPE4 Yes L-- is the one-to eight-character name of the control
program to be automatically loaded in the 3704/3705 at
system IPL time. If an automatic load is not desired,
omit this operan d.
Note: Failure to code the CPNAME operand on the RDEVICE
macro for the 3704/3705 base address causes VM/370 to
mark the device "not operational" at IPL time. The
cluster on that 3704/3705 is therefore unusable.
is the native address (load address) of the 3704/3705 that controls the physical line (5) This operand is
required for correct operation of VM/370 recovery
management for emulator lines based on a 3704/3705. This operand is valid only if ADAPTER=IBM1, TELE2, or
BseA .. Part 1. rlanning for System Generation 65
3704/3705 Control Program r- I IBM 3704 Communications IBM 3705 Communications Controller I Controller I __ I Al, B 1, C 1, Dl I A1 16K A2, B2, C2, D2 I A2 32K B3, C3, D3 I A3 48K 3705-1 B4, C4, D4 I A4 64K C5, D5 I C6, D6 I D7 , D8 I , E 1, F 1, G 1, Hl I E2, F2, G2, H2 I E3, F3, G3, H3 I 3705-11 E4, F4, G4, H4 I E5, F5, G5, H5 I E6, F6, G6, H6 , 'F.7: F7: : R'7 , E8, F8, G8, H8
L
Figure 11 IBM 3704/3705 Models SPECIAL CONSIDERATIONS FOR CODING THE RDEVICE MACRO The 3704/3705 Consequently, the
complex.
Communications Controllers
control program generation
If the 3704/3705 is to be run in emUlation mode:
have
for the
16K
48K 80K 112K
144K
176K 208K 240K 32K 64K 96K
128K 160K 192K 22UK 256K
varied uses. 3704/3705 is Use the (cuu,nn) form of the ADDRESS operand to generate multiple RDEVBLOKs. the appropriate name for CPNAME. To generate additional emulator lines for the same 3704/3705, use the
following coding guidelines on subsequent RDEVICE macros: Omit the CPTYPE, CPNAME, and MODEL operands. Specify the ADAPTER as IBM1, TELE2, or BSCA, as appropriate.
For ADAPTER=IBM 1 (or TELE2), the SETADDR operand must also be
specified, exactly as if the device were a 2702 or 2703. If you use the (cuu,nn) form of the ADDRESS operand to generate
multiple RDEVBLOKs and also specify the CPNAME and ADAPTER=TYPE1 operands on the RDEVICE macro, the additional RDEVBLOKs are generated as
ADAPTER=IBM1 and SETADDR=4.