Page ot GC;.lU-HW1-1U AS upaat.ea l'larcn .3, Dy '.rl'U •• bN-,:J-UIIO Configurations (Terminals)
The IBM 3767 Communication Terminal, ,Models 1 and 2, is supported when
it operates as an IBM 2741 Communication Terminal and is attached to a 3704 or 3705 Communications Controller. It requires the following
features on either switched or nonswitched point-to-point lines: 2741 START/STOP (17113) EBCDIC (19391) or Correspondence (19381) keyboard Duplexed, switched or nonswitched line (#9404) for connecting to a Western Electric 103A2 (or equivalent data set) One of the following:
--EIA Interface with Clock (#3719) at 300 bps --1200 (15505 or The following features, although not
convenience and usability of the terminal:
required, enhance the Alternate Character Set (#1291), plus a defined character subset for
the keyboard:
--If the primary character set is Correspondence (19381), the
alternate character set can b.e APL (#9383) or EBCDIC (19382). --If the primary character set is EBCDIC (19391), the alternate
character set can be APL (#9393) or Correspondence (19392). Line control is PTTC/EBCD with this feature. Acoustic Coupler (#1110) at 300 bps
Transmission Control Units VM/370 supports the following transmission control units: IBK 2701 Data Adapter Unit IBK 2702 Transmission Control IBK 2703 Transmission Centrol IBM Integrated Communications Attachment (ICA), (#4640) IBM 3704, 3705-1, and 3705-11 Communications Controllers 2701 REQUIRED FEATURES I. For line control of CPT-TWX (Kodel 33/35) terminals and the 3101 I display terminals, the Telegraph Adapter Type II (#7885) is required. For 2770, 2780, 3270, 3770 (as a 2770; 3776 also as a 3780), and 3780 the following are required: --Synchronous Data Adapter Type II (#7698)
--EBCDIC code (#9060) --EBCDIC transparency (#8029) 120 IBK VK/370 Planning and System Generation Guide
Page of GC20-1801-10 As Updated March 3, 1980 by TNL GN25-0776 Configurations (TCUs) For 1050 and 2741 terminals, the following are required: --IBK Terminal Adapter Type I, Kodel II ('4640) --Selective Speed, 134.5 bps ('9581) --2741 Break Feature RPQ #M53193, and Break Command RPQ '858492 The Expanded Capability feature (13815) is required if there are: --More than two low speed adapters (either IBM Type I Model II, or
Telegraph Type II), or --More than one high speed adapter (Synchronous Data Adapter Type
II), or
--One high speed and at least one low speed adapter attached to the
same 2701. The Expansion Feature (#3855; is required for each line adapter after the first. 2702 REQUIRED AND OPTIONAL FEATURES For 1050 and 2741 terminals, the following are required:
--Terminal Control Base for IBM Terminal Control ('9696) --IBM Terminal Control Type I ('4615) --Selective Speed, 134.5 bps ('-9684) --Type I Terminal Interrupt ('8200) --Data Set Line Adapter (#3233) or IBM Line Adapter (#4635), 4-wire IBM Terminal Control Type I ('4615) I. For line control of (Model 33135) terminals and the 3101 I display terminals, the following are required:
--Terminal Control Base for Telegraph Terminal Control ('9697) --Telegraph Terminal Control Type II ('7912) --Pluggable End Characters (return key qenerates an interrupt) RPQ tE62920, optional
--Data Set Line Adapter (#3233)
--Terminal Control Expansion ('7935), required only if both of the
terminal bases (#9697 and #7912) are attached to the same 2702. The 31 Line Expansion <'7955) is supported as needed." 2703 REQUIRED AND OPTIONAL FEATURES For 1050 and 2741 terminals, the following are required: --Start-Stop Base Type I (#7505) or Type II ('7506) --IBM Terminal Control Base <'4619) --IBM Ter minal Control Type I (14696) --Line Speed Option, 134.5 bps (14878) --Type I Terminal Interrupt (18200) --Data Line Set (13205) and/or IBM Line Set 1B (#4687) Part 1. Planning for System Generation 121
Previous Page Next Page